Free referral, Miami-Dade County waterfrontCall (645) 300-7447
Miami-DadeSeawall Contractor Guide

Miami-Dade County, Class I permits

Seawall Repair in Miami

Seawall repair in Miami comes with a permit question before any price. Miami-Dade County requires a Class I Permit before most work in, on, over or upon tidal waters, and the county lists seawall work among the jobs that need one.

Fixing it where it stands

The county's short form covers building, repairing or replacing a seawall at the mean high water line or up to 18 inches waterward of where it is now. Since July 2025 it also covers walls whose main support piles stick out up to 14 inches, as long as the new wall ends up no more than 18 inches waterward of those piles. Florida law uses the same 18 inch figure for restoring a wall. Going farther out falls outside that.

The state text keeps county and city rules in force. So the county permit still matters.

Who else signs off

Depending on the address, the city, the South Florida Water Management District, the Florida Department of Environmental Protection or the Army Corps can have a say too. County fees are based on construction cost. Most short form permits are good for 2 years.

Before work starts, check the contractor's license.

What the county code and Florida Statutes say

The county paragraph is the current code text, including the sentence added by Ordinance No. 25-73 (July 1, 2025).

Miami-Dade County Code, Sec. 24-48.2(I)(A)(1)

(I) Short Form Permit Application:

(A) When permissible: A short form permit application may be accepted by the Department for the following types of work:

(1) The construction, repair, or replacement of seawalls or bulkheads, including the minimum filling or dredging necessary for installation, at the mean high water line or no more than 18 inches waterward of their existing location. In addition, such construction, repair, or replacement shall also be eligible for a short form permit where there are seawall/bulkhead primary support piles (such as king piles, T-piles, or other structural piles) that extend a total of no more than 14 inches waterward, provided that the reconstructed, repaired, or replaced seawall or bulkhead is in total no more than 18 inches waterward of the existing primary support piles.

Florida Statutes, s. 403.813(1), opening paragraph and paragraphs (e) and (o)

(1) A permit is not required under this chapter, chapter 373, chapter 61-691, Laws of Florida, or chapter 25214 or chapter 25270, 1949, Laws of Florida, and a local government may not require a person claiming this exception to provide further department verification, for activities associated with the following types of projects; however, except as otherwise provided in this subsection, this subsection does not relieve an applicant from any requirement to obtain permission to use or occupy lands owned by the Board of Trustees of the Internal Improvement Trust Fund or a water management district in its governmental or proprietary capacity or from complying with applicable local pollution control programs authorized under this chapter or other requirements of county and municipal governments:

(e) The restoration of seawalls at their previous locations or upland of, or within 18 inches waterward of, their previous locations. This may not affect the permitting requirements of chapter 161, and department rules shall clearly indicate that this exception does not constitute an exception from the permitting requirements of chapter 161.

(o) The construction of private seawalls in wetlands or other surface waters when such construction is between and adjoins at both ends existing seawalls; follows a continuous and uniform seawall construction line with the existing seawalls; is not more than 150 feet in length; and does not violate existing water quality standards, impede navigation, or affect flood control. However, in estuaries and lagoons the construction of vertical seawalls is limited to the circumstances and purposes stated in s. 373.414(5)(b)1.-4. This paragraph does not affect the permitting requirements of chapter 161, and department rules must clearly indicate that this exception does not constitute an exception from the permitting requirements of chapter 161.

Want a licensed contractor to look at the wall?